Scope

This European Standard applies to signalling and telecommunication apparatus that is installed inside the railway environment. Signalling and telecommunication apparatus mounted in vehicles is covered by FprEN 50121 3 2, signalling and telecommunication apparatus installed inside substation and connected to substation equipment is covered by FprEN 50121 5.
This European Standard specifies limits for emission and immunity and provides performance criteria for signalling and telecommunications (S&T) apparatus (including power supply systems belonging to S&T) which may interfere with other apparatus inside the railway environment, or increase the total emissions for the railway environment and so risk causing Electro-Magnetic Interference (EMI) to apparatus outside the railway system.
Apparatus which complies with the emission levels of EN 61000 6 4 will meet the emission requirements of this standard provided that emissions from any DC power port are within the emissions limits specified for AC power ports.
The immunity levels given in this standard apply for
- vital equipment such as interlocking or command and control,
- apparatus inside 3 m zone,
- ports of apparatus inside 10 m zone with connection inside 3 m zone,
- ports of apparatus inside 10 m zone with cable length > 30 m.
Other apparatus not covered by at least one of these given cases should be in compliance with EN 61000 6 2.
The immunity levels given for the apparatus will in most cases allow the apparatus to perform as intended inside the railway environment. The immunity level establishes a common reference for evaluating the performance of the apparatus when subject to interference resulting from direct exposure of the apparatus and associated cables to a radio frequency field, or by coupling of the interference from a remote source.
If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirement in this standard are not intended to be applicable to the intentional transmission from a radio-transmitter as defined by the ITU.
Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC related standard for radio equipment.
The standard does not specify basic personal safety requirements for apparatus such as protection against electric shock, unsafe operation, insulation co-ordination and related dielectric tests. The requirements were developed for and are applicable to this set of apparatus when operating under normal conditions. Fault conditions of the apparatus have not been taken into account.
Test requirements are specified for each port considered.
The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified.
For products in the scope of EN 61000 3 2, EN 61000 3 3, EN 61000 3 11 or EN 61000 3 12 the requirements of those standards also apply.
Testing methods are given in the basic standards listed in Clause 2, Normative references.
These specific provisions are to be used in conjunction with the general provisions in EN 50121 1.
The immunity and emission levels do not of themselves guarantee that the integration of apparatus will necessarily be satisfactory. The standard cannot cover all the possible configurations of the apparatus, but the test levels are sufficient to achieve satisfactory EMC in the majority of cases.

Related legislation

Legislation related to this standard

2004/108/EC

Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC

2008/57/EC

DIRECTIVE 2008/57/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 17 June 2008 on the interoperability of the rail system within the Community (Recast)

2014/30/EU

Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)

Life cycle

PREVIOUSLY

WITHDRAWN
EN 50121-4:2006

WITHDRAWN
EN 50121-4:2006/corrigendum May 2008

NOW

WITHDRAWN
EN 50121-4:2015
99.60 Withdrawal effective
Oct 24, 2019

REVISED BY

PUBLISHED
EN 50121-4:2016