EN 4838-005:2019

Aerospace series - Arc fault circuit breakers, single-pole, temperature compensated, rated current 3 A to 25 A - 115 V a.c. 400 Hz Constant Frequency - Part 005: With polarized signal contact - Product standard EN 4838-005:2019

Publication date:   Oct 16, 2019

General information

90.93   Standard confirmed   Jan 21, 2025

CEN

ASD-STAN Aerospace

European Norm

49.060   Aerospace electric equipment and systems

Buying

Published

Language in which you want to receive the document.

Scope

This European Standard specifies the required characteristics for single-pole, arc fault circuit breakers rated currents from 3 A to 25 A, switching capacity 65 In, for use in aircraft electrical systems. Their operating temperatures are between  40 °C to 85 °C at a maximum altitude of Z = 15 000 m. The thermal protection is temperature compensated and operates between  55 °C and 125 °C.
These circuit breaker are operated by a push-pull type single pushbutton (actuator), with delayed action "trip-free" tripping.
They will continue to function up to the short-circuit current.

Life cycle

NOW

PUBLISHED
EN 4838-005:2019
90.93 Standard confirmed
Jan 21, 2025




Access Genorma App Everywhere

Get fast and easy access to top European and International standards (EN, ISO, IEC) via your mobile phone, tablet or the web.