EN 449:2002/prA1

Specification for dedicated liquefied petroleum gas appliances - Domestic flueless space heaters (including diffusive catalytic combustion heaters) EN 449:2002/prA1

General information

50.60 Close of voting. Proof returned by secretariat   Jul 26, 2007

CEN

CEN/TC 181 Appliances and leisure vehicle installations using liquefied petroleum gas and appliances using natural gas for outdoor use

European Norm

97.100.20   Gas heaters

Scope

5.18 Overheating of the LPG container and its LPG container installation compartment
5.18.1 Overheating of the walls of the LPG container installation compartment
Under the conditions defined in 6.18, the temperature rise above ambient temperature of the LPG container installation compartment walls shall not exceed 30 K at any point that is likely to come in contact with the flexible tube and/or the gas cylinder.

Related legislation

Legislation related to this standard

90/396/EEC

Appliances burning gaseous fuels

Life cycle

PREVIOUSLY

WITHDRAWN
EN 449:2002

NOW

IN_DEVELOPMENT
EN 449:2002/prA1
50.60 Close of voting. Proof returned by secretariat
Jul 26, 2007