1.1 Scope of EN 1993-1-5
(1) This document provides rules for structural design of stiffened and unstiffened nominally flat plates which are subject to in-plane forces.
(2) Non-uniform stress distributions due to shear lag, in-plane load introduction and plate buckling are covered. The effects of out-of-plane loading are outside the scope of this document.
NOTE 1 The rules in this part complement the rules for class 1, 2, 3 and 4 sections, see EN 1993-1-1.
NOTE 2 For the design of slender plates which are subject to repeated direct stress and/or shear and also fatigue due to out-of-plane bending of plate elements ("breathing"), see EN 1993-2 and EN 1993-6.
NOTE 3 For the effects of out-of-plane loading and for the combination of in-plane effects and out-of-plane loading effects, see EN 1993-2 and EN 1993-1-7.
(3) Single plate elements are considered as nominally flat where the curvature radius r in the direction perpendicular to the compression satisfies, as illustrated in Figure 1.1:
r≥b^2/t (1.1)
where
b is the panel width;
t is the plate thickness.
Figure 1.1 - Definition of plate curvature
1.2 Assumptions
(1) Unless specifically stated, EN 1990, the EN 1991 series and EN 1993-1-1 apply.
(2) The design methods given in EN 1993-1-5 are applicable if
- the execution quality is as specified in EN 1090-2 and
- the construction materials and products used are as specified in the relevant parts of the EN 1993 series or in the relevant material product specifications.
Legislation related to this standard
Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec
WITHDRAWN
EN 1993-1-5:2006
WITHDRAWN
EN 1993-1-5:2006/AC:2009
WITHDRAWN
EN 1993-1-5:2006/A1:2017
WITHDRAWN
EN 1993-1-5:2006/A2:2019
PUBLISHED
EN 1993-1-5:2024
60.60
Standard published
Mar 20, 2024