EN 16691:2015

Water quality - Determination of selected polycyclic aromatic hydrocarbons (PAH) in whole water samples - Method using solid phase extraction (SPE) with SPE-disks combined with gas chromatography mass spectrometry (GC-MS) EN 16691:2015

Publication date:   Nov 16, 2015

General information

90.93 Standard confirmed   Feb 9, 2022

CEN

CEN/TC 230 Water analysis

European Norm

13.060.50   Examination of water for chemical substances

Buying

Published

Language in which you want to receive the document.

Scope

This European Standard specifies a method for the determination of 7 polycyclic aromatic hydrocarbons (PAH) in whole water samples as listed in Table 1. The method uses solid-phase disk extraction (SPE-disk) in combination with gas chromatography-mass spectrometry (GC-MS). It is applicable to the analysis of PAHs in surface water, which may contain suspended particulate matter (SPM) up to 500 mg/l (whole water samples), drinking water and groundwater.
The lower and upper limit of the working range depends on the matrix, on the specific compound to be analyzed and on the sensitivity of the mass spectrometric detection unit. The limit of quantification (LOQ) determined in the validation is given in Table 1. The upper limit of the working range is approximately 2 000 ng/l.
This method is, with some modification may also be suitable for the analysis of waste water. This method is applicable to other PAH ), provided the method is validated for each PAH.
(...)

Related legislation

Legislation related to this standard

2000/60/EC

Directive 2000/60/EC of the European Parliament and of the Council of 23 October 2000 establishing a framework for Community action in the field of water policy (substitutes Directive Reference 01/991 - Common Position on WFD)