EN 16339:2013

Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling EN 16339:2013

Publication date:   Sep 16, 2013

General information

90.93 Standard confirmed   Mar 14, 2019

CEN

CEN/TC 264 Air quality

European Norm

13.040.20   Ambient atmospheres

Buying

Published

Language in which you want to receive the document.

Scope

This European Standard specifies a method for the sampling and analysis of NO2 in ambient air using diffusive sampling followed by extraction and analysis by colorimetry or ion chromatography (IC). It can be used for the NO2 measurement in a concentration range of approximately 3 µg/m³ to 130 µg/m3. A sample is typically collected for a period of 1 to 4 weeks [13], with exposure periods depending on the design of the samplers and the concentration levels of NO2.
Several sorbents can be used for trapping NO2 in ambient air using a diffusive sampler. This standard specifies the application of triethanolamine as the reagent.
Nitrous acid and peroxyacetyl nitrate are the major chemical interferences of sorption by triethanolamine. However, in ambient air monitoring over long sampling times, both contaminants are generally present at low concentrations relative to NO2. Moreover, these species can also interfere with the measurement of NO2 when applying the EU reference method for NO2 monitoring based on chemiluminescence (see [2]).
This standard describes the application of a tube-type sampler with either a cylindrical or a slightly conical tube. Its typical uptake rate is about 1 cm3/min. Only for this sampler type sufficient evidence of validation has been found in a literature survey [12].
The relative expanded uncertainty of NO2 measurements performed using these tube-type diffusive samplers can potentially be lower than 25 % for individual measurements. When aggregating results to form annual average values, the relative expanded uncertainty can be further reduced to levels below 15 % due to the reduction of random effects on uncertainty [6].

Related legislation

Legislation related to this standard

1999/30/EC

Limit values for sulphur dioxide, nitrogen dioxide and oxides of nitrogen, particulate matter and lead in ambient air

96/62/EC

Ambient air quality assessment and management

Life cycle

NOW

PUBLISHED
EN 16339:2013
90.93 Standard confirmed
Mar 14, 2019

REVISED BY

IN_DEVELOPMENT
FprEN 16339