99.60 Withdrawal effective May 4, 2022
CEN
CEN/TC 107 Prefabricated district heating and district cooling pipe system
European Norm
23.040.07 Pipelines and its parts for district heat
Withdrawn
This European Standard provides requirements and test methods for flexible, pre-insulated, directly buried district heating pipe assemblies with metallic service pipes and bonding between the layers of the pipes and thermal insulation materials of polyurethane or polyisocyanurate foam. Casing pipe shall be made from polyethylene.
This European Standard is valid for maximum operating temperatures up to 140 °C and pressures up to 25 bar for a design lifetime of at least 30 years.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this European Standard.
WITHDRAWN
EN 15632-4:2009
99.60
Withdrawal effective
May 4, 2022
PUBLISHED
EN 15632-4:2022