90.93 Standard confirmed Oct 11, 2019
CEN
CEN/TC 137 Assessment of workplace exposure to chemical and biological agents
European Norm
13.040.30 Workplace atmospheres
This European Standard specifies the continuous drop test apparatus and associated test method for the reproducible production of dust from a bulk material under standard conditions, and the measurement of the inhalable and respirable fractions of this dust, with reference to existing European Standards, where relevant (see Clause 6).
The continuous drop method intends to simulate dust generation processes where there are continuous falling operations (conveying, discharging, filling, refilling, weighing, sacking, metering, loading, unloading etc.) and where dust is liberated by winnowing during falling. It can be modified to measure the thoracic fraction as well, but this modification is not described in this European Standard. It differs from the rotating drum method presented in EN 15051 2 in that in this European Standard, the bulk material is dropped only once, but continuously, while in EN 15051 2, the same bulk material is repeatedly dropped.
Furthermore, this European Standard specifies the environmental conditions, the sample handling and analytical procedures and the method of calculating and presenting the results. A classification scheme for dustiness is specified, to provide a standardised way to express and communicate the results to users of the bulk materials.
This European Standard is applicable to powdered, granular or pelletised bulk materials.
This European Standard is not applicable to test the dust released when solid bulk materials are mechanically treated (e.g. cut, crushed) or to evaluate handling procedures for the bulk materials.
WITHDRAWN
EN 15051:2006
PUBLISHED
EN 15051-3:2013
90.93
Standard confirmed
Oct 11, 2019
IN_DEVELOPMENT
prEN 15051-3