EN 14907:2005

Ambient air quality - Standard gravimetric measurement method for the determination of the PM2,5 mass fraction of suspended particulate matter EN 14907:2005

Publication date:   Aug 10, 2006

General information

99.60 Withdrawal effective   May 21, 2014

CEN

CEN/TC 264 Air quality

European Norm

13.040.20   Ambient atmospheres

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This European Standard describes a standard method for determining the PM2,5 mass concentration of suspended particulate matter in ambient air by sampling the particulate matter on filters and weighing them by means of a balance.
Measurements are made over a sampling period of about 24 h, and in line with the Directive, are expressed as µg/m3, where the volume of air is the volume at ambient conditions near the inlet at the time of sampling.
The range of application of the standard is from 1 µg/m3 (i.e. the limit of detection of the standard measurement method expressed as its uncertainty) up to 120 µg/m3 (i.e. the maximum concentration level observed during the field study undertaken by CEN/TC 264/WG 15 to validate the standard).
NOTE Although the standard is not validated for concentrations over 120 µg/m3, its range of application could well be extended to commonly encountered ambient concentrations up to circa 200 µg/m3 when using glass or quartz fibre filters. At these high concentrations and particulate mass loadings no filter clogging is to be expected. Also the flow rate can be easily maintained at the nominal setting.
The equivalence procedure in Annex A specifies two approaches, depending on whether the candidate method differs slightly or fundamentally from the standard method.
In the former case, involving only slight differences from the standard method ("variations on a theme") Annex A provides a restricted procedure to compare only the pertinent differences, instead of a full field test. This part of the annex serves to give practical guidance for determining equivalence for measurement methods commonly used in monitoring networks, and includes examples of common variations to the standard method, such as different filter storing or conditioning procedures and the variation of the standard method for the application as automated filter changer.

Related legislation

Legislation related to this standard

1999/30/EC

Limit values for sulphur dioxide, nitrogen dioxide and oxides of nitrogen, particulate matter and lead in ambient air

96/62/EC

Ambient air quality assessment and management

Life cycle

NOW

WITHDRAWN
EN 14907:2005
99.60 Withdrawal effective
May 21, 2014

REVISED BY

WITHDRAWN
EN 12341:2014