99.60 Withdrawal effective Dec 14, 2022
CEN
CEN/TC 264 Air quality
European Norm
13.040.40 Stationary source emissions
This European Standard specifies specific requirements on automated measuring systems (AMS) for monitoring of total mercury. It is derived from EN 14181, which is the general document on the quality assurance of AMS. It is only applicable in conjunction with EN 14181.
This European Standard sets specific requirements for the quality assurance levels and annual surveillance test as specified in EN 14181, for mercury AMS used for proving that the mercury emissions from a source are compliant with emission limits below 0,5 mg/m3 ) (standard conditions) in ducted gaseous streams. This European Standard is applicable by direct correlation with the standard reference method (SRM) described in EN 13211.
This European Standard is primarily developed for emissions from waste incinerators. From a technical point of view, it may be applied to other processes, for which measurement at an emission limit is required with defined uncertainty.
Legislation related to this standard
Directive 2000/76/EC of the European Parliament and of the Council of 4 December 2000 on the incineration of waste
WITHDRAWN
EN 14884:2005
99.60
Withdrawal effective
Dec 14, 2022
PUBLISHED
EN 14884:2022