99.60 Withdrawal effective Dec 19, 2018
CEN
CEN/TC 444 Environmental characterization of solid matrices
Technical Specification
13.030.01 Wastes in general
Withdrawn
This Technical Specification specifies a method for quantitative determination of 17 2,3,7,8-chlorine substituted dibenzo-p-dioxins and dibenzofurans and dioxin-like polychlorinated biphenyls in sludge, treated biowaste and soil using liquid column chromatographic clean-up methods and GC/HRMS.
The analytes to be determined with this Technical Specification are listed in Table 2.
(...)
The limit of detection depends on the kind of sample, the congener, the equipment used and the quality of chemicals used for extraction and clean-up. Under the conditions specified in this Technical Specification, limits of detection better than 1 ng/kg (expressed as dry matter) can be achieved.
This method is "performance based". It is permitted to modify the method if all performance criteria given in this method are met.
NOTE In principle this method can also be applied for sediments, mineral wastes and for vegetation. It is the responsibility of the user of this Technical Specification to validate the application for these matrices.
Legislation related to this standard
Protection of the environment, and in particular of the soil, when sewage sludge is used in agriculture
WITHDRAWN
CEN/TS 16190:2012
99.60
Withdrawal effective
Dec 19, 2018
PUBLISHED
EN 16190:2018