cen:proj:85023

District heating pipes — Factory made flexible pipe systems — Part 1: Classification, general requirements and test methods

General information

10.99   New project approved   Nov 17, 2026

CEN

CEN/TC 107 Prefabricated district heating and district cooling pipe system

European Norm

Scope

This document specifies classification, general requirements and test methods for flexible, factory made, buried district heating pipe systems.
This document is intended to be used in conjunction with part 2, 3 or 4, as applicable.
Depending on the pipe assembly (see Table 4), this document is applicable to a maximum operating temperature of 95 °C (part 2 and 3) and a maximum operating temperature of 120 °C (for part 4) and design pressures of 0,6 MPa to 2,5 MPa.
The pipe systems are designed for a service life of at least 30 years. For pipe systems with plastic service pipes, the respective temperature profiles are specified in EN 15632 2 and EN 15632 3.
NOTE For the transport of other liquids, for example potable water, additional requirements can be applicable