cen:proj:83956

Factory-made double skin metal faced insulating panels - Part 6: Installation

General information

10.99   New project approved   May 18, 2026

CEN

CEN/TC 128 Roof covering products for discontinuous laying and products for wall cladding

European Norm

Scope

This document specifies minimum requirements for the planning and installation of wall cladding and roof coverings using structural
and non-structural sandwich panels that are harmonised according to prEN 14509-1 and prEN 14509-2, comprising two metal faces
and an insulation core.
This document covers the installation of sandwich panels with through-fixings and hidden fixing systems.
This document does not cover the installation of:
- safety devices for individuals or groups of people;
- sandwich panels with an insulation core made of phenolic foam (PF)
- elements suspended from the panel faces;
- outer cladding and attachment of decorative covers;
- rooftop structures or installation of equipment on the panels (photovoltaic glass modules, solar thermal collectors,
etc.);
- any additional thermal insulation on the inner face of the panels;

Life cycle

NOW

IN_DEVELOPMENT
cen:proj:83956
10.99 New project approved
May 18, 2026