ISO 10313:1993

Ambient air — Determination of the mass concentration of ozone — Chemiluminescence method ISO 10313:1993

Publication date:   Apr 22, 1993

General information

90.93 Standard confirmed   Jun 15, 2023

ISO

ISO/TC 146/SC 3 Ambient atmospheres

International Standard

13.040.20   Ambient atmospheres

Buying

Published

Language in which you want to receive the document.

Scope

The method specified is based on drawing continuously, at a constant flow rate, an air sample through a particle filter before it enters the chemiluminescence analyser. It then flows into a reaction chamber where it is mixed with an excess flow of ethylene. Ozone and ethylene react instantaneously to produce light in the visible region (maximum at about 400 nm). The emitted light intensity is proportional to the concentration of ozone in the air sample and is measured by a photomultiplier tube. Applies to determination of the mass concentration of ozone between 2 µg/m^3 and 10 mg/m^3 at the reference conditions.

Life cycle

NOW

PUBLISHED
ISO 10313:1993
90.93 Standard confirmed
Jun 15, 2023

CORRIGENDA / AMENDMENTS

IN_DEVELOPMENT
ISO 10313:1993/DAmd 1