IEC 61788-23 ED3:2024 (EN) addresses a test method for the determination of the residual resistance ratio (RRR), rRRR, of cavity-grade niobium. This method is intended for high-purity niobium grades with 150 < rRRR < 600. The test method is valid for specimens with rectangular or round cross-section, cross-sectional area greater than 1 mm2 but less than 20 mm2, and a length not less than 10 nor more than 25 times the width or diameter.
PUBLISHED
IEC 61788-23:2021 ED2
IN_DEVELOPMENT
IEC 61788-23 ED3
60.00
Standard under publication
Apr 12, 2024