ISO 16283-3:2016

Acoustics — Field measurement of sound insulation in buildings and of building elements — Part 3: Façade sound insulation ISO 16283-3:2016

Publication date:   Feb 1, 2016

General information

90.93 Standard confirmed   Oct 6, 2021

ISO

ISO/TC 43/SC 2 Building acoustics

International Standard

91.060.10   Walls. Partitions. Façades | 91.120.20   Acoustics in building. Sound insulation

Buying

Published

Language in which you want to receive the document.

Scope

ISO 16283-3:2016 specifies procedures to determine the airborne sound insulation of façade elements (element methods) and whole façades (global methods) using sound pressure measurements. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz.
The test results can be used to quantify, assess, and compare the airborne sound insulation in unfurnished or furnished rooms where the sound field can or cannot approximate to a diffuse field. The measured airborne sound insulation is frequency-dependent and can be converted into a single number quantity to characterize the acoustic performance using the rating procedures in ISO 717-1.

Life cycle

PREVIOUSLY

WITHDRAWN
ISO 140-5:1998

NOW

PUBLISHED
ISO 16283-3:2016
90.93 Standard confirmed
Oct 6, 2021

REVISED BY

IN_DEVELOPMENT
ISO/PWI 16283-3