IEC 61290-4-1:2016 ED2

Optical amplifiers - Test methods - Part 4-1: Gain transient parameters - Two-wavelength method IEC 61290-4-1:2016 ED2

Publication date:   Sep 26, 2016

General information

60.60 Standard published   Sep 26, 2016

IEC

TC 86/SC 86C

International Standard

33.180.30   Optic amplifiers

Buying

Published

Language in which you want to receive the document.

Scope

IEC 61290-4-1:2016 applies to optical amplifiers (OAs) using active fibres (optical fibre amplifiers (OFAs)) containing rare-earth dopants including erbium-doped fibre amplifiers (EDFAs) and optically amplified elementary sub-systems. These amplifiers are commercially available and widely deployed in service provider networks. The object of document is to provide the general background for OFA transients and related parameters, and to describe a standard test method for accurate and reliable measurement of the following transient parameters:
- channel addition or removal transient gain overshoot and transient net gain overshoot;
- channel addition or removal transient gain undershoot and transient net gain undershoot;
- channel addition or removal gain offset;
- channel addition or removal transient gain response time constant (settling time). This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- extended the applicability from only EDFAs to all OFAs;
- updated definitions for consistency with other documents in the IEC 61290-4 series. Keywords: optical amplifiers (OAs), optical fibre amplifiers (OFAs), rare-earth dopants, erbium-doped fibre amplifiers

Life cycle

PREVIOUSLY

WITHDRAWN
IEC 61290-4-1:2011 ED1

NOW

PUBLISHED
IEC 61290-4-1:2016 ED2
60.60 Standard published