CLC/TS 50131-12:2016

Alarm systems - Intrusion and hold-up systems - Part 12: Methods and requirements for setting and unsetting of Intruder Alarm Systems (IAS) CLC/TS 50131-12:2016

Publication date:   Jan 18, 2017

General information

60.60 Standard published   Nov 4, 2016

CENELEC

CLC/TC 79 Alarm systems

Technical Specification

13.320   Alarm and warning systems

Buying

Published

Language in which you want to receive the document.

Scope

This Technical Specification provides recommendations for those methods of setting and unsetting an Intrusion Alarm System (IAS) complying with EN 50131-1 that will reduce unwanted alarms arising from "operator error" in setting and unsetting the IAS and provide confidence that the conditions in which the system is installed are conducive to system reliability during the "set" period.
This document details optional methods by which these goals may be achieved, either in isolation, or in conjunction with verification methods.
These recommendations should be incorporated into the respective standards in the EN 50131 series.
This Technical Specification also provides (in Annex A) recommendations for equipment and (in Annex C) associated test requirements, in order to permit the manufacture of standardized equipment to provide the functionality needed by an IAS to meet these recommendations.
NOTE This standard includes requirements that are additional to those in EN 50131-1 which are relevant when the respective method of setting and unsetting is implemented.

Life cycle

NOW

PUBLISHED
CLC/TS 50131-12:2016
60.60 Standard published
Nov 4, 2016