EN 12350-4:2019

Testing fresh concrete - Part 4: Degree of compactability EN 12350-4:2019

Publication date:   Sep 19, 2019

General information

60.60 Standard published   Jun 19, 2019

CEN

CEN/TC 104 Concrete and related products

European Norm

91.100.30   Concrete and concrete products

Buying

Published

Language in which you want to receive the document.

Scope

This document specifies a method for determining the consistence of fresh concrete by determining the degree of compactability.
The test is suitable for specimens having a declared value of D of the coarsest fraction of aggregates actually used in the concrete (Dmax) not greater than 63 mm.
If the degree of compactability is less than 1,04 or more than 1,46, the concrete has a consistence for which the degree of compactability test is not suitable.

Life cycle

PREVIOUSLY

WITHDRAWN
EN 12350-4:2009

NOW

PUBLISHED
EN 12350-4:2019
60.60 Standard published