EN 50465:2015

Gas appliances - Combined heat and power appliance of nominal heat input inferior or equal to 70 kW EN 50465:2015

General information

60.60 Standard published   Jan 23, 2015

CEN/CENELEC

CEN/CLC/JTC 17 Fuel Cell Gas Appliances with Combined Heat and Power

European Norm

27.070   Fuel cells | 97.100.20   Gas heaters

Scope

This European Standard specifies the requirements and test methods for the construction, safety, fitness for purpose, rational use of energy and the marking of a micro combined heat and power appliance; (hereafter referred to as “mCHP appliance”).
This European Standard applies to mCHP appliances of types B22, B23, B32, B33, B52, B53, C1, C3, C42, C43 C52, C53, C62, C63, C82, C83 and C9 based on the classifications of CEN/TR 1749:
– that use one or more supplied gases of the three gas families at the pressures stated in EN 437,
– where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 ºC during normal operation,
– where the maximum operating pressure in the
- heating water circuit does not exceed 6 bar,
- domestic hot water circuit (if installed) does not exceed 10 bar,
– which are either intended to be installed indoors or outdoors in a partially protected place,
– which are intended to produce hot water either by the instantaneous or storage principle,
– which have a maximum heat input (based on net calorific value) not exceeding 70 kW,
– which are designed for sealed or open water systems.
NOTE 1 For applications where the maximum allowable water temperature exceeds 110 ºC or where volume multiplied by maximum allowable pressure exceeds 50 bar litres, further requirements may be necessary to comply with the essential requirements of Directive 97/23/EC (Pressure Equipment Directive (PED)).
NOTE 2 For mCHP appliances with constructions that might not be fully covered by this European Standard or by another specific standard, the risk associated with the alternative construction will be assessed.
NOTE 3 This EN includes formulae and methods intended to produce values required by implementation measures of the ErP Directive 2009/125/EC and Labelling Directive 2010/30/EU.
NOTE 4  EN 13203-4 will specify the assessment of energy consumption for domestic hot water production of gas combined heat and power appliances (mCHP).
This European Standard does not contain the requirements necessary for appliance capable of producing electrical energy without using the thermal energy.
This European Standard does not cover all the requirements for mCHP appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex DD).

Related legislation

Legislation related to this standard

2009/142/EC

Appliances burning gaseous fuels

811/2013

Commission Delegated Regulation (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device

813/2013

Commission Regulation (EU) No 813/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for space heaters and combination heaters

Life cycle

PREVIOUSLY

WITHDRAWN
EN 50465:2008

NOW

PUBLISHED
EN 50465:2015
60.60 Standard published
Jan 23, 2015

CORRIGENDA / AMENDMENTS

PUBLISHED
EN 50465:2015/A1:2019