EN 12618-3:2004

Products and systems for the protection and repair of concrete structures - Test methods - Part 3: Determination of the adhesion of injection products, with or without thermal cycling - Slant shear method EN 12618-3:2004

Publication date:   Mar 25, 2005

General information

90.93 Standard confirmed   Nov 13, 2020

CEN

CEN/TC 104 Concrete and related products

European Norm

91.080.40   Concrete structures

Buying

Published

Language in which you want to receive the document.

Scope

This Part of this European Standard describes the method for determining the slant shear bond strength of all injection products intended to restore the integrity of cracked concrete and covered by prEN 1504-5.
The test may be performed upon cracks injected in the dry, damp, wet or with water flowing through them. It should always be carried out after the appropriate period of curing under the standard conditions of test detailed below, but may additionally be performed upon a further set of specimens after a period of artificial ageing by thermal cycling.
Whilst the testing of the repaired crack is normally by short term static load, it may also be performed as a creep test by long term static load, or as a dynamic test by the application of a cyclic load.

Related legislation

Legislation related to this standard

89/106/EEC

Construction products

305/2011

Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec